肌骨超声图像的特征检测算法研究及拼接实现

颜焕欢,张培镇,王伊侬,李璇,阳维,王青(南方医科大学;南方医科大学南方医院)

摘 要
目的 肌骨超声宽景图像易出现解剖结构错位、断裂等现象,其成像算法中的特征检测影响宽景图像的质量,它也是超声图像配准、分析等算法的关键步骤,但目前仍未有相关研究明确指出适合提取肌骨超声图像特征点的算法。本文利用结合SIFT描述子的FAST算法以及SIFT、SURF、ORB算法对肌骨超声图像序列进行图像拼接,并对各算法的性能进行比较评估,为肌骨超声图像配准、宽景成像提供可参考的特征检测解决方案。方法 本文采集5组正常股四头肌的超声图像序列,每组再采样10张图像。利用经典的图像拼接算法进行肌骨图像的特征检测以及图像拼接。首先,分别利用上述四种算法提取肌骨超声图像的特征点;之后,对特征点进行特征匹配,估算出图像间的形变矩阵;最后,对所有待拼接的图像进行坐标变换以及融合处理,得到拼接全景图,并在特征检测性能、特征匹配性能、图像配准性能以及拼接效果等方面对四种算法进行比较评估。结果 实验结果表明,与SIFT、SURF、ORB算法相比,FAST-SIFT算法所提取的特征点分布更均匀,可以检测到大部分肌纤维的端点,且特征点检测时间最短,约4ms,其平均匹配对数最多,是其它特征检测算法的2-5倍,其互信息和归一化互相关系数均值分别为1.016和0.748,均高于其他三种特征检测算法,表明其图像配准精度更高。且FAST-SIFT算法的图像拼接效果更好,没有明显的解剖结构错位、断裂、拼接不连贯等现象。结论 与SIFT、SURF、ORB算法相比,FAST-SIFT算法是更适合提取肌骨超声图像特征点的特征检测算法,在图像配准精度等方面都具有一定的优势。
关键词
Study on feature detection algorithm of musculoskeletal ultrasound imageand its application of image stitching

Yan Huanhuan,Zhang Peizhen,Wang Yinong,Li Xuan,Yang Wei,Wang Qing(Southern Medical University)

Abstract
Objective Musculoskeletal ultrasound (MSKUS) is an imaging diagnosis method commonly applied in the diagnosis and treatment of musculoskeletal diseases. The feature detection of MSKUS image plays an important role in image registration, image analysis of MSKUS images and extended field-of-view ultrasound imaging, requiring extraction of the effective feature points. However, the contrast of the ultrasound image is low, and speckle noise and image artifacts are presented in the MSKUS images. These limitations negatively affect the extraction of the feature points of MSKUS image. In consequence, the accuracy of image registration and the quality of image stitching are affected, it may lead to misalignment and fracture of anatomical structure on the MSKUS panoramic image. It has not been clearly determined that an algorithm which is suitable for detecting feature points of MSKUS images The objectives of this study are to evaluate the performance of four local feature detection algorithms on stitching MSKUS sequence images, including Scale Invariant Feature Transform (SIFT), Speeded-up Robust Features (SURF), Oriented FAST and Rotated BRIEF (ORB), and Features from Accelerated Segment Test (FAST) combined with SIFT descriptor, and to provide a basis and reference solution of feature detection for MSKUS image registration and Extended Field-of-View Ultrasound imaging in future research. Method Ultrasound image sequences of the quadriceps muscles in 5 normal human subjects are collected. From the image sequence of each subject, 10 images are resampled every 5 frames for image feature detection and image stitching. The classical image stitching method proposed by Brown is adopted in this paper, which includes the following three main steps. First, the feature points of the MSKUS image are extracted by SIFT, SURF, ORB and FAST-SIFT respectively. Then, based on the obtained feature points and their corresponding feature point descriptors, the Nearest Neighbor Distance Ratio (NNDR) method is applied to achieve rough feature matching and the Random Sample Consensus (RANSAC) algorithm is used to realize fine feature matching. The projection transformation matrix is taken as the basic model to estimate the optimal deformation matrix between the two images. Finally, the deformation matrix between the two images is used to obtain the internal parameters of the camera and the external parameters of the camera. These camera parameters can be used to transform the 10 images into the coordinate system of the reference image. After coordinate transformation, all the 10 images are stitched together. Then, the panorama of MSKUS is post-processed by using the maximum flow minimum cut algorithm to find the unwell-stitched overlapped area. The multi-band fusion is used to reduce the artificial and rough seam zones. The MSKUS panorama is eventually obtained. To evaluate the performance of the four algorithms SIFT, SURF, and ORB algorithms, FAST-SIFT, detection of feature points, feature matching, image registration, and image stitching are assessed. Result The experimental results show that in comparison with to SIFT, SURF, and ORB algorithms, FAST-SIFT is able to extract more uniform distribution feature points and detect most of the end points of the muscle fibers. Furthermore, the detection time of feature points using FAST-SIFT is much shorter, about 4ms. The average number of matching points in FAST-SIFT is the largest, which is 2 - 5 times as many as other feature detection algorithms. FAST-SIFT algorithm has the highest correct rate of feature matching. The mean value of mutual information and normalized cross-correlation coefficient of FAST-SIFT are 1.016 and 0.748, respectively, which are higher than other three feature detection algorithms, indicating that the accuracy of image registration is higher. Moreover, the stitched panorama of MSKUS using the FAST-SIFT algorithm shows better image stitching, i.e. no obvious misalignment and fracture of anatomical structure are found. Conclusion In comparison with SIFT, SURF and ORB, FAST-SIFT algorithm is more suitable to extract the feature points of MSKUS image. It has advantages in the distribution of feature points, the detection time of feature points, the average number of matching points, the correct rate of feature matching, image registration accuracy and image stitching result.
Keywords
QQ在线


订阅号|日报